An oil fired boiler service will include:
- Inspection of the oil tank and visible parts of the oil supply line
- Inspection of oil filters, de-aerators, check valves and fire valves
- Inspection of burner components for wear and adjustment
- Cleaning of the combustion chamber and flueways
- Test firing of the boiler to check operation and safety cut-outs
- Fine tuning of the boiler using flue gas analysis equipment
- Checking of the system controls and thermostats
The oil nozzle is replaced during every service
An AGA Rayburn service will include:
- Inspection of the oil tank and visible parts of the oil supply line
- Inspection of oil filters, de-aerators, check valves and fire valves
- Removal of carbon from the burner, shells and bundy tube
- Cleaning of the combustion chamber and flueways
- Reassembly of burner and base level check
- Installation of new wicks
- Check low and high setting oil valve flow rates (if required)
- Checking of the system controls
- Relight burner and check correct flame picture and characteristics